Siemens Opcenter X — A vulnerability has been identified in Opcenter X (All versions < V2604).

Description · from the CVE record

A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application.

Affected

ProductAffectedFixed inSource
Opcenter X< V2604V2604CNA

Scores by source

siemens (CNA)10.0CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
siemens (CNA)10.0CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:L/SI:H/SA:H
CISA ADPSSVCExploitation: none · Automatable: yes · Technical impact: total

References

refcert-portal.siemens.com/productcert/html/ssa-096828.html