Paper/Archive/CVE-2026-39462

CVE-2026-39462

SenseLive X3050 — SenseLive X3050 Insufficiently Protected Credentials

Description · from the CVE record

A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.

Affected

ProductAffectedFixed inSource
X3050V1.523–CNA

Scores by source

icscert (CNA)9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
icscert (CNA)8.1CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA ADPSSVCExploitation: none · Automatable: no · Technical impact: total

References

refcisa.gov/news-events/ics-advisories/icsa-26-111-12refsenselive.io/contactrefgithub.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json