CVE-2026-15203
Danfoss iC7-Automation SP — Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software
Description · from the CVE record
Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
Affected
ProductAffectedFixed inSource
iC7-Automation SP≤ 2025.3.3–CNA
iC7-Marine≤ 2025.8.19–CNA
iC7-Hybrid≤ 2025.10.300845–CNA
Scores by source
Danfoss (CNA)9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L
CISA ADPSSVCExploitation: none · Automatable: yes · Technical impact: total