CVE-2025-69426
RUCKUS Networks vRIoT IOT Controller — Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE
Description · from the CVE record
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
Affected
ProductAffectedFixed inSource
vRIoT IOT Controller2.3.0.0 (GA) – < 3.0.0.0 (GA)3.0.0.0 (GA)CNA
vRIoT IOT Controller2.3.1.0 (MR) – < 3.0.0.0 (GA)3.0.0.0 (GA)CNA
vRIoT IOT Controller2.4.0.0 (GA) – < 3.0.0.0 (GA)3.0.0.0 (GA)CNA
Scores by source
VulnCheck (CNA)10.0CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
CISA ADPSSVCExploitation: none · Automatable: yes · Technical impact: total