Paper/Archive/CVE-2025-3498

CVE-2025-3498

Radiflow iSAP Smart Collector — Unauthenticated modification of Radiflow iSAP Smart Collector configuration

Description · from the CVE record

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

Affected

ProductAffectedFixed inSource
iSAP Smart Collector1.20 – < 3.02-13.02-1CNA

Scores by source

ENISA (CNA)9.9CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L
CISA ADPSSVCExploitation: none · Automatable: yes · Technical impact: partial

References

refcvcn.gov.it/cvcn/cve/CVE-2025-3498