Paper/Archive/CVE-2025-11784

CVE-2025-11784

SGE-PLC1000 SGE-PLC50 Circutor — Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50

Description · from the CVE record

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Affected

ProductAffectedFixed inSource
Circutor9.0.2–CNA

Scores by source

NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
INCIBE (CNA)8.5CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H
CISA ADPSSVCExploitation: none · Automatable: no · Technical impact: total

References

refincibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0