Paper/Archive/CVE-2024-39872

CVE-2024-39872

Siemens SINEMA Remote Connect Server — A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1).

Description · from the CVE record

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate their privileges on the underlying OS level.

Affected

ProductAffectedFixed inSource
SINEMA Remote Connect Server< V3.2 SP1V3.2 SP1CNA
sinema_remote_connect_server< 3.2_sp13.2_sp1CISA-ADP

Scores by source

NVD9.9CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
siemens (CNA)9.6CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N/E:P/RL:O/RC:C
siemens (CNA)9.3CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H
CISA ADPSSVCExploitation: none · Automatable: no · Technical impact: total

References

refcert-portal.siemens.com/productcert/html/ssa-381581.html