CVE-2024-3907

Tenda AC500 — Tenda AC500 setcfm formSetCfm stack-based overflow

Description · from the CVE record

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected

ProductAffectedFixed inSource
AC5002.0.1.9(1307)–CNA
ac500-2.0.1.9(1307)–CISA-ADP

Scores by source

NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
VulDB (CNA)8.8CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VulDB (CNA)8.8CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CISA ADPSSVCExploitation: poc · Automatable: no · Technical impact: partial

References

writeupvuldb.com/?id.261143refvuldb.com/?ctiid.261143writeupvuldb.com/?submit.313802exploitgithub.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md