Paper/Archive/CVE-2024-10943

CVE-2024-10943

Rockwell Automation FactoryTalk Updater — FactoryTalk® Updater Authentication Bypass

Description · from the CVE record

An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.

Affected

ProductAffectedFixed inSource
FactoryTalk UpdaterV4.00.00-4.10.00–CNA
factorytalk_updater4.00.00 – 4.20.00–CISA-ADP

Scores by source

Rockwell (CNA)9.1CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
Rockwell (CNA)9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
CISA ADPSSVCExploitation: none · Automatable: yes · Technical impact: total

References

refrockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1710.html