Paper/Archive/CVE-2023-33218

CVE-2023-33218

IDEMIA SIGMA Lite & Lite + — Stack Buffer Overflow in a binary run at upgrade startup

Description · from the CVE record

The Parameter Zone Read and Parameter Zone Write command handlers allow performing a Stack buffer overflow. This could potentially lead to a Remote Code execution on the targeted device.

Affected

ProductAffectedFixed inSource
SIGMA Lite & Lite +< 4.15.54.15.5CNA
SIGMA Wide< 4.15.54.15.5CNA
SIGMA Extreme< 4.15.54.15.5CNA
MorphoWave Compact/XP< 2.12.22.12.2CNA
VisionPass< 2.12.22.12.2CNA
MorphoWave SP< 1.2.71.2.7CNA

Scores by source

NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
IDEMIA (CNA)9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

References

refidemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf