CVE-2023-0321
Campbell Scientific CR6 — Disclosure of Sensitive Information on Campbell Scientific Products
Description · from the CVE record
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
Affected
ProductAffectedFixed inSource
CR6all version–CNA
CR300all version–CNA
CR800all version–CNA
CR1000all version–CNA
CR3000all version–CNA
Scores by source
INCIBE (CNA)9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
NVD9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
CISA ADPSSVCExploitation: poc · Automatable: yes · Technical impact: partial