Paper/Archive/CVE-2022-37454

CVE-2022-37454

Siemens RUGGEDCOM APE1808 — The Keccak XKCP SHA-3 reference implementation before fdc6fef has an integer overflow and resultant buffer overflow that allows attackers…

Description · from the CVE record

The Keccak XKCP SHA-3 reference implementation before fdc6fef has an integer overflow and resultant buffer overflow that allows attackers to execute arbitrary code or eliminate expected cryptographic properties. This occurs in the sponge function interface.

Affected

ProductAffectedFixed inSource
n/asee advisory–CNA
RUGGEDCOM APE1808all versions–siemens-SADP
SIMATIC S7-1500 CPU 1518-4 PN/DP MFPV3.1.0 – < V3.1.5V3.1.5siemens-SADP
SIMATIC S7-1500 CPU 1518-4 PN/DP MFPV3.1.0 – < V3.1.5V3.1.5siemens-SADP
SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPV3.1.0 – < V3.1.5V3.1.5siemens-SADP
SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPV3.1.0 – < V3.1.5V3.1.5siemens-SADP
SIPLUS S7-1500 CPU 1518-4 PN/DP MFPV3.1.0 – < V3.1.5V3.1.5siemens-SADP

Scores by source

CISA ADP9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CISA ADPSSVCExploitation: poc · Automatable: yes · Technical impact: total

References

refcsrc.nist.gov/projects/hash-functions/sha-3-projectrefmouha.be/sha-3-buffer-overflowrefnews.ycombinator.com/item?id=33281106refgithub.com/XKCP/XKCP/security/advisories/GHSA-6w4m-2xhg-2658reflists.debian.org/debian-lts-announce/2022/10/msg00041.htmlreflists.debian.org/debian-lts-announce/2022/11/msg00000.htmlreflists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CMIEXLMTW5GO36HTFFWIPB3OHZXCT3G4refdebian.org/security/2022/dsa-5267refdebian.org/security/2022/dsa-5269reflists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3ALQ6BDDPX5HU5YBQOBMDVAA2TSGDKIJrefeprint.iacr.org/2023/331refnews.ycombinator.com/item?id=35050307refsecurity.gentoo.org/glsa/202305-02refsecurity.netapp.com/advisory/ntap-20230203-0001refcert-portal.siemens.com/productcert/html/ssa-398330.htmlrefcert-portal.siemens.com/productcert/html/ssa-806742.htmlrefcert-portal.siemens.com/productcert/html/ssa-455250.html