Paper/Archive/CVE-2022-37011

CVE-2022-37011

Siemens Mendix SAML (Mendix 7 compatible) — A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All…

Description · from the CVE record

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0). Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled.

Affected

ProductAffectedFixed inSource
Mendix SAML (Mendix 7 compatible)All versions < V1.17.0–CNA
Mendix SAML (Mendix 8 compatible)All versions < V2.3.0–CNA
Mendix SAML (Mendix 9 compatible, New Track)All versions < V3.3.1–CNA
Mendix SAML (Mendix 9 compatible, Upgrade Track)All versions < V3.3.0–CNA

Scores by source

NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

References