Paper/Archive/CVE-2021-31890

CVE-2021-31890

Siemens Capital Embedded AR Classic 431-422 — A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versio…

Description · from the CVE record

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)

Affected

ProductAffectedFixed inSource
Capital Embedded AR Classic 431-422all versions–CNA
Capital Embedded AR Classic R20-11< V2303V2303CNA
PLUSCONTROL 1st GenAll versions–CNA
SIMOTICS CONNECT 400All versions < V0.5.0.0–CNA
SIMOTICS CONNECT 400All versions < V1.0.0.0–CNA

Scores by source

NVD9.1CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
siemens (CNA)7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

References

refcert-portal.siemens.com/productcert/pdf/ssa-114589.pdfrefcert-portal.siemens.com/productcert/pdf/ssa-044112.pdfrefcert-portal.siemens.com/productcert/pdf/ssa-620288.pdfrefcert-portal.siemens.com/productcert/pdf/ssa-845392.pdfrefcert-portal.siemens.com/productcert/pdf/ssa-223353.pdfrefcert-portal.siemens.com/productcert/html/ssa-114589.htmlrefcert-portal.siemens.com/productcert/html/ssa-044112.htmlrefcert-portal.siemens.com/productcert/html/ssa-620288.htmlrefcert-portal.siemens.com/productcert/html/ssa-845392.htmlrefcert-portal.siemens.com/productcert/html/ssa-223353.html