CVE-2020-10272
Mobile Industrial Robots A/S MiR100 — RVD#2554: MiR ROS computational graph presents no authentication mechanisms
Description · from the CVE record
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
Affected
ProductAffectedFixed inSource
MiR100v2.8.1.1 and before–CNA
Scores by source
Alias (CNA)10.0CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
NVD9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H